Eicher (VECV) · 125 kVA / 100 kW · Domestic

These are just for visual representation and for actual images of any model please connect.
Domestic market · LANVS engineered genset package on Eicher (VECV) power platform.
Included with LANVS supply, installation support and after-sales service.
Included with LANVS supply, installation support and after-sales service.
Included with LANVS supply, installation support and after-sales service.
Included with LANVS supply, installation support and after-sales service.
LE 125 KVA
125 kVA / 100 kW
Eicher E694 · 6 cyl
174 A
250 L
| Parameter | Value |
|---|---|
| Prime Rating (as per ISO 8528) | 125 kVA |
| Prime Power (as per ISO 8528) | 100 kW |
| Frequency | 50 Hz |
| Rated Speed | 1500 RPM |
| Power Factor | 0.8 lagging |
| DEF / AdBlue Capacity | 27 litres |
| Voltage / Phase | 3 Phase (415V) |
| Noise Level (free field, ISO 3744 / ISO 8528 Part-10) | <75 dBA |
| Fuel Tank Capacity | 250 litres |
| Engine Specification | |
| Engine | E694 |
| Engine Brand | Eicher |
| No. of Cylinders | 6 |
| Rated Power | 155 BHP |
| Bore × Stroke | 100 × 120 mm |
| Displacement | 5.65 litres |
| Compression Ratio | 17:1 |
| Method of Aspiration | TCIC |
| Coupling | SAE11.5 / SAE2 |
| Direction of Rotation from Flywheel End | Anticlockwise when viewed from flywheel end |
| Air Filter | Dry type |
| Engine Cooling | Liquid cooling |
| Coolant Quantity | 22 L |
| Ambient Capability of Radiator | <50 °C |
| Tripping Temperature of HCT Switch on Engine | 105 °C |
| Starter Motor Voltage | 12 V |
| Battery Charging Alternator | 12 V / 55 A |
| Fuel Pump | CRDi |
| Type of Governor | EMS (electronic) class A1 |
| Exhaust Treatment System | DOC + SCR |
| Dimensions (L × W × H) | 3300 × 1300 × 1860 mm |
| DG Protections | Oil pressure sensor, coolant temperature sensor, urea sensor, thermal cut-off in starter, boost air pressure sensor, fuel pressure, water in fuel, fuel temperature switch, oil temperature sensor, overload, overspeed, current unbalancing, charging alternator / V belt, service due (failed to start – failed to stop) |
| Display Parameters | Running time hours, current, voltage, engine RPM, frequency, engine temperature and oil pressure, battery voltage, service due hour, kVA, PF, kW, kWh, fuel and DEF level |
| Other Features | In-built oil cooler, piston cooling jet, 4 valves per cylinder, engine oil and coolant pre-filled |
| Mobil Oil Sump Capacity | 21.5 L |
| Alternator | |
| Make | Mecc Alte / Stamford |
| Rating of AC Generator | 125 kVA / 100 kW |
| Rated Speed / Voltage (line to line) / Phase / Pole | 1500 RPM / 415 V / 3 phase / 4 pole |
| Rated Current | 174 A |
| Frequency / Power Factor / Winding Pitch | 50 Hz / 0.8 PF / pitch 2/3 |
| Voltage Regulation (with 4% engine governing) | 1% |
| Insulation Class / Temperature Rise Limit | H |
| Overload | 10% overload for 1 hour once in 12 hours |
| Total Harmonic Distortion | No-load <2% |
| Nominal Ambient Temperature / Altitude | −15 to +40 °C / ≤ 1000 m |
| Type of Alternator | Brushless / self-excited and self-regulated / double layer lap winding / IP23 |
| Analogue AVR Model | R120 / AS440 |
| Standard Control Panel | |
| Control Panel Type with AMF Sensing | Manual / IP54 / with AMF sensing |
| Controller Make / Model / Modes of Operation | DEIF (SGC 120) / Deep Sea (4520) / equivalent / auto, manual and remote start-stop |
| Display | Full graphics LCD, backlit, with power saving for extended lifetime |
| MCB / MCCB Current | 200 A |
| Battery Charging Point | 12 V DC / 10 A |
| Current Transformer (CT) Coils — Primary Current | 200 A |
| Current Transformer (CT) Coils — Class | Class 1 |
| kWh Meter | Analog counter type |
| Remote Information & Monitoring Module (RIMM) | Yes |
| Audible Annunciation System (AAS) as per CPCB Norms | Yes |
| Battery | |
| Battery Make / Capacity | (TATA Green / Equivalent) 130 Ah |
| Warranty | 2 years / 24 months or 5000 hrs from commissioning, whichever is earlier, subject to use of VECV / Eicher oil, VECV / Eicher genuine filters, LANVS coolant, VECV / Eicher DEF, and service sourced from LANVS or its authorised representative / associate |
| Service Schedule | 50 hrs: oil change and oil filter; then every 700 hrs or 1 year, whichever is earlier |
Figures are taken from the LANVS catalogue for this rating.